August 24th, 2008 admin No comments

How can I turn a drum trigger into a momentary switch?

So I found out on my drum module the bass drum is just an on off switch. So what I need to do now is figure out a way to take the electrical impulse I get from my bass drum and send it to a switch that closes when electricity is ran through it, then re opens. Anyone know of anyway that can be done?

You will need some support electronics.
Check out "one shot timer" on google. Use this to capture the trigger signal.
Here is a cicuit that might work. Replace the open switch with the trigger wires.

http://www.recumbents.com/WISIL/timing/555%20timer%20ckt.pdf

Genuine Cisco N4K 4005I XPX Nexus 4005 Switch Module for IBM BladeCenter
Genuine Cisco N4K 4005I XPX Nexus 4005 Switch Module for IBM BladeCenter
Paypal   US $10,780.00
Cisco RSP 720 3CXL GE Route Switch Processor Module
Cisco RSP 720 3CXL GE Route Switch Processor Module
Paypal   US $9,100.00
CISCO ENHANCED ETHERSWITCH SERVICE MODULE ADVANCED SWITCH 16 PORTS SMES3G16P
CISCO ENHANCED ETHERSWITCH SERVICE MODULE ADVANCED SWITCH 16 PORTS SMES3G16P
Paypal   US $1,692.39
IBM NORTEL SWITCH ETHERNET 10GBPS 14 PORTS PLUG IN MODULE 32R1783
IBM NORTEL SWITCH ETHERNET 10GBPS 14 PORTS PLUG IN MODULE 32R1783
Paypal   US $1,601.95
CISCO UBR RFSW 1DS RF Switch Downstream Switching Module
CISCO UBR RFSW 1DS RF Switch Downstream Switching Module
Paypal   US $1,517.09
CISCO UBR RFSW 1US RF Switch Upstream Switching Module
CISCO UBR RFSW 1US RF Switch Upstream Switching Module
Paypal   US $1,517.09
NEW IBM 32R1892 Cisco Intelligent Gigabit Switch Module
NEW IBM 32R1892 Cisco Intelligent Gigabit Switch Module
Paypal   US $1,500.00
Cisco NME XD 48ES 2S P Switch Module 1 Month Warranty
Cisco NME XD 48ES 2S P Switch Module 1 Month Warranty
Paypal   US $1,182.84
MGX RPM PR 256 CISCO PROCESSOR SWITCH MODULE 2 REVS AVAILABLE
MGX RPM PR 256 CISCO PROCESSOR SWITCH MODULE 2 REVS AVAILABLE
Paypal   US $1,150.00
Cisco DWDM 15530 15530 CPU CPU Switch Module 90 Day Hardware Warranty
Cisco DWDM 15530 15530 CPU CPU Switch Module 90 Day Hardware Warranty
Paypal   US $995.00
ENTERASYS X4 FM X Series Switch Fabric Module for X4 C Chassis
ENTERASYS X4 FM X Series Switch Fabric Module for X4 C Chassis
Paypal   US $995.00
Cisco WS X6608 E1 1YearWarranty 2XAvailable Switch Module ASK MORE QTY
Cisco WS X6608 E1 1YearWarranty 2XAvailable Switch Module ASK MORE QTY
Paypal   US $950.00
IBM NORTEL LAYER 2 3 COPPER ETHERNET SWITCH MODULE 32R1869
IBM NORTEL LAYER 2 3 COPPER ETHERNET SWITCH MODULE 32R1869
Paypal   US $941.69
IBM NORTEL LAYER 2 3 COP GBE SWITCH MODULE 32R1866
IBM NORTEL LAYER 2 3 COP GBE SWITCH MODULE 32R1866
Paypal   US $941.69
Cisco SFS7008P SFM K9 SFS 7008P Switch Fabric Module
Cisco SFS7008P SFM K9 SFS 7008P Switch Fabric Module
Paypal   US $899.00
3COM 3C17510 Switch 8800 PoE Entry Module SALE
3COM 3C17510 Switch 8800 PoE Entry Module SALE
Paypal   US $899.00
IBM Nortel Layer 2 7 GigaBit LAN Module For BladeCenter Switch 73P9057
IBM Nortel Layer 2 7 GigaBit LAN Module For BladeCenter Switch 73P9057
Paypal   US $866.44
PXM 1 CISCO MGX 8850 PROCESSOR SWITCH MODULE BA9AY0PEAA 800 07888 03
PXM 1 CISCO MGX 8850 PROCESSOR SWITCH MODULE BA9AY0PEAA 800 07888 03
Paypal   US $575.00
HP PROCURVE SWITCH GL MODULE 10 100 1000 20 PORTS J490869001
HP PROCURVE SWITCH GL MODULE 10 100 1000 20 PORTS J490869001
Paypal   US $529.70
Brocade 20 Ports 4Gb SAN Switch Module SBCEBFCSW4
Brocade 20 Ports 4Gb SAN Switch Module SBCEBFCSW4
Paypal   US $500.00
Riverstone Router RS 8600 Router Switch with Modules G8M CM3 G8M AO3BM 02
Riverstone Router RS 8600 Router Switch with Modules G8M CM3 G8M AO3BM 02
Paypal   US $499.99
Cisco Catalyst 6500 WS X6548 GE TX 10 100 1000BaseT Ethernet Switch Module
Cisco Catalyst 6500 WS X6548 GE TX 10 100 1000BaseT Ethernet Switch Module
Paypal   US $443.57
Cisco WS X6548 GE TX 48 Port Gigabit Switch Module for WS C6500 6509 6548
Cisco WS X6548 GE TX 48 Port Gigabit Switch Module for WS C6500 6509 6548
Paypal   US $400.00
Force10 Force 10 Networks CC E SFM Switch Fabric Module
Force10 Force 10 Networks CC E SFM Switch Fabric Module
Paypal   US $375.00
NEW Adtran NetVanta 1000Base LX SFP Switch Module
NEW Adtran NetVanta 1000Base LX SFP Switch Module
Paypal   US $348.99
Cisco WS X6148 GE TX 48 Port Gigabit Switch Module
Cisco WS X6148 GE TX 48 Port Gigabit Switch Module
Paypal   US $345.00
View Page:   1  2  3

Description of Protective Switches Operation

Two articles in two last year's numbers of the magazine Er have presented a survey of operation of overcurrent protective devices, based on the use of traditional safety fuses. A similar survey can be presented also for the protective devices, manufactured as various protective switches.

These devices are in the first place:

* circuit breakers complying with the standard SIST EN 60898 – circuit breakers for overcurrent protection for household and similar installations;

* residual current circuit breakers without overcurrent protection built-in, complying with the standard SIST EN 61008;

* residual current circuit breakers without overcurrent protection built-in, for the use in household and similar applications (RCCB);

* residual current circuit breakers with overcurrent protection, complying with the standard SIST EN 61009 - residual current circuit breakers for the use in household and similar applications (RCCO).

Basic representation of a protective switch state is the position of the on-off button on the protective switch that can be down below, in the middle or above. As a rule, the operation of protective switches doesn't depend on their location, and can usually be mounted in any position, therefore the manufacturer must very clearly indicate which position of the on-off button or switch handle corresponds to the position "switched-on" or "switched-off". This is also one of requirements of all standards for such products. The manufacturers usually fulfil the requirement by printing this information on the product.

For better overview and better reliability the manufacturers usually place the indication 0/I or ON/OFF directly on ON-OFF buttons.

But the possibility of an error still remains on the protective device itself. The position of the ON-OFF button can be changed, but not the state of contacts inside the device (because the contacts are e.g. welded). Therefore more and more protective devices represent actual situation of contacts within the protective device: red flag – contacts of the switch are still closed; green flag – the contacts are open.

Such contact condition indication must ensure that the "green condition" isn't shown if the contacts are still closed, regardless of the position of switching mechanism and ON-OFF button.

It is often important to find out switched-off condition of the protective switch in the shortest possible time, because an urgent process may have been interrupted by switching off. And the protective switch might be installed in a relatively remote and badly visible place. In such cases the so-called auxiliary and signal switches are used. The difference between them is as follows: An auxiliary switch always changes the state of its contacts when the protective switch is switched; a signal switch (also named alarm switch), however, only changes the state of its contacts when the protective device is switched off due to a failure (manual switching-off doesn't change the contacts' condition).

So the task of these switches is to send information – remote signalling – to a remote location, about the changed condition of protective device. Consequently, they report a power supply interruption. This remote signalling is carried out through the contacts of an auxiliary switch that can switch on or off an acoustic or other type of signalization.

As for the mounting method of auxiliary switches, the following two situations can be distinguished:

* built-in auxiliary switches (they are incorporated into protective devices by the manufacturer);

* built-on auxiliary switches (a mechanical building-on in the field is possible).

For practical reasons the second variant is, of course, more appreciated.

With regard to the principle of operation the switches can be mechanical or electronic. For protective switches primarily mechanical versions are used. There is also a standard with which such products must comply, that is SIST EN 62019 – Electrical Committee – Circuit breakers and similar devices to be used in household area – Auxiliary contacts' unit.

In practice there can be found primarily auxiliary switches that by their external shape correspond to a basic protective switch, while their width equals one half of the standard module (9 mm). It is important to read the operating instruction, enclosed to the auxiliary switches before their installation. Namely, some of them have to be mounted when the main device is switched on, whereas for the others it must be switched off. The least, what can be caused by an incorrect installation is the malfunction of the auxiliary switch. Moreover, it can cause its damage, or even a damage of the main protective switch. A mechanical building-on can be usually carried out by means of clamps that can be metallic or plastic. With the older types adhesive tapes were still used, but they used to slacken due to aging or dirt, thus causing malfunctions.

An example of building-on an auxiliary switch to the circuit breaker is shown in Figure 4. The auxiliary switch is built on to the left-hand side, and the circuit breaker must be switched-off during the installation.

An example of technical specification for an auxiliary switch:

* rated voltage: 230 V a.c. or 110 V d.c.

* rated current: 6 A a.c. or 1 A d.c.

* conditional short-circuit capacity: 1 kA (with a preceding safety fuse cartridge of 20 A);

* contacts: 1 x a (closing), 1 x b (opening); the most often used combination;

* connecting terminals: 1 – 4 mm2.

Some important data are also printed on the side surface of the product (permissible screw torque for connecting terminals, marking of connecting terminals and a like.

For timely reporting switch-off conditions of protective switches, the auxiliary switches have been already now very often used in industry and electrical distribution. Improvement in the quality of electrical installation, and the use of so-called intelligent installations will certainly increase their use in house installations as well.